Software version 0303
Hardware version 0100; 0101; 0200; 0300
Date 2011-10-28
Description This firmware is applicable for:
GAF900, GAF500, HAF900, HAF500,

- Changed range audio gains to [-144, +12] dB
- Added CRC events for SDI inputs
- Fixed Embedding in 1080p23,98 and 1080psf23,98 video formats
- Added Silence events for local audio inputs
- Added Delay-Bypass setting

Updated ATC-Embedder block: When ATC-Packets are not correctly placed in
HANC/VANC at SDI-Input, or when more than 1 ATC-Packets is present within SDI
in HANC and VANC at the same time, the ATC-Embedder duplicated these
wrong-placed-packets. This duplication is solved.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 0202
Hardware version 0100; 0101; 0200; 0300
Date 2010-11-18
Description This firmware is applicable for:
GAF900, GAF500, HAF900, HAF500,

First Release

Changed:
- Fixed: Stabilised main pll circuit which could cause crc errors/green flashes on the output
- Fixed: 0dBFS-In setting (500 version only)
- Fixed: 1080p23,98 support
- Fixed: Possible artifacts while switching between sources when locked to ref
- Added GPI support for switching presets
- Added ATC Transparency
- Added Output-to-ref-timing table
- Added Silence detection for audio
- Added Line-lock setting
- Added switch-line status items
- Changed: reduced separated Emb-AB-Mode and Emb-CD-Mode to a single Emb-Mode for all embedder blocks
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.