Skip to content

Download DLA42 firmware

DLA42 firmware

Software version 0510
Hardware version 0100; 0101; 0102; 0200
Date 2012-02-08
Description Linear Acoustic:
- This version is intended for version 1.9.0 of the Up/Down/AutomaxII.

Changes:
- Added Fixed preset according to EBU-R128 standard.
- Fixed GPI Offset menu item which was not functioning.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 0410
Hardware version 0100; 0101; 0102; 0200
Date 2011-12-01
Description Linear Acoustic:
- This version is intended for version 1.9.0 of the Up/Down/AutomaxII.

Changes:
- Lockmode menu-options changed from: AES1, AES4, Mastercard, Ref1 and Ref2 to AES1, AES4, Mastercard, Reference.
Reference selection is now done by new menu-item Reference Source. This option has a dual function. Reference source not only depicts
to which refernce the cards audio should lock when the lockmode is set to Reference but it is also used to indicate to which reference the Metadata is locked.
Metadata is only generated when the correct ref is selected and present this is done to ensure a clean switch of metadata in the guardband.

- Main output and stereo output are not designated as "dB" anymore as this was incorrect.

- Fixed the generation of CRC packets for metadata. These packets could be incorrect in previous versions

- Fixed the issue when using the output level of the loudness processor as the dialoque level for generating metadata there was no change in dialoque level
if the output level changed.

- Fixed the use of revert metadata presets when there is a loss of incoming metadata and the corresponding menu-item is set tot external metadata as source.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 0209
Hardware version 0100; 0101; 0102
Date 2011-02-23
Description Linear Acoustic:
- This version is intended for version 1.9.0 of the Up/Down/AutomaxII.

Changes:
- The preset structure has changed over the entire DLAxx range. The first 6 presets in all products are fixed to
the standard Linear Acoustic Presets. Preset 7 to 16 are user adjustable and are at default an exact copy of presets 1 to 6.
Presets 15 and 16 are a copy of preset 1 and also user adjustable.

- The Output level for the loudness processing engine can be set to the approximate loudness level. This is an approximation of
the loudness level therefore we added another menu-option called 2.0 or 5.1 Offset to Output/Dial Level which can be used to fine tune
the output level.

- It is no longer possible to select channel number higher then 8 for the input in the I/O Control Tab when the card is not used with a mastercard.

- The Quadspeed bus is updated to it's latest state which included re-insertion of processed channels on the Quadspeed bus.

- GPI Controls are updated to resemble the DLA44 GPI Control. Please see the manual for a more detailed explanation
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 0104
Hardware version 0100; 0101; 0102
Date 2010-12-09
Description - First Release
- This version is intended for DualStereo DSP 1 version 1.6
- This version is intended for DualStereo DSP 2 version 1.6
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.