Skip to content

Download HXT110 firmware

HXT110 firmware

Software version 4218
Hardware version 0101; 0102
Date 2012-04-16
Description This card may be updated through the front ethernet connector on the card, which is quicker as compared to programming with Cortex / Synapse setup. For instructions please refer to the Synapse module reprogramming guide (available on http://www.axon.tv/EN/support/downloads/manuals ) under Chapter 2 re-programming Linux based cards or contact support.

Included in the zipfile are the Cortex Layout Forms (CLF files), please copy them to your cortex installation directory for the latest graphical user interface : {.....Cortex_install_dir....}\Forms\Device\{filename.clf}

- Added timecode insertion option to switch timecode on/off
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 3918
Hardware version 0101; 0102
Date 2012-01-31
Description This card may be updated through the front ethernet connector on the card, which is quicker as compared to programming with Cortex / Synapse setup. For instructions please refer to the Synapse module reprogramming guide (available on http://www.axon.tv/EN/support/downloads/manuals ) under Chapter 2 re-programming Linux based cards or contact support.

Included in the zipfile are the Cortex Layout Forms (CLF files), please copy them to your cortex installation directory for the latest graphical user interface : {.....Cortex_install_dir....}\Forms\Device\{filename.clf}

Fixed: Horizontal allignment of the image.
Added: Active input status item.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 3317
Hardware version 0101; 0102
Date 2011-10-13
Description This card may be updated through the front ethernet connector on the card, which is quicker as compared to programming with Cortex / Synapse setup. For instructions please refer to the Synapse module reprogramming guide (available on http://www.axon.tv/EN/support/downloads/manuals ) under Chapter 2 re-programming Linux based cards or contact support.

Included in the zipfile are the Cortex Layout Forms (CLF files), please copy them to your cortex installation directory for the latest graphical user interface : {.....Cortex_install_dir....}\Forms\Device\{filename.clf}

Fixed: Horizontal allignment of the image.
Added: Active input status item.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 2612
Hardware version 0101; 0102
Date 2011-06-27
Description This card may be updated through the front ethernet connector on the card, which is quicker as compared to programming with Cortex / Synapse setup. For instructions please refer to the Synapse module reprogramming guide (available on http://www.axon.tv/EN/support/downloads/manuals ) under Chapter 2 re-programming Linux based cards or contact support.

Please find the Restricted Delivery Announcement included in this download.
Also included are the Cortex Layout Forms (CLF files), please copy them to your cortex installation directory for the latest graphical user interface : {.....Cortex_install_dir....}\Forms\Device\{filename.clf}

Added:
- Anamorphic scaling with 702 pixels in SD-SDI instead of 720.
- Heartbeat for audio and video memory to prevent lock-up.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 2009
Hardware version 0101; 0102
Date 2011-02-21
Description This card may be updated through the front ethernet connector on the card, which is quicker as compared to programming with Cortex / Synapse setup. For instructions please refer to the Synapse module reprogramming guide (available on http://www.axon.tv/EN/support/downloads/manuals ) under Chapter 2 re-programming Linux based cards or contact support.

Please find the Restricted Delivery Announcement included in this download.
Also included are the Cortex Layout Forms (CLF files), please copy them to your cortex installation directory for the latest graphical user interface : {.....Cortex_install_dir....}\Forms\Device\{filename.clf}

Added:
- OP47 and WST detection.
- OP47 to WST conversion and viceversa.
- Vertical Ancillary (VANC) data transparency. For the VANC transparency the user may manually select 6 lines to be carried through the card transparently. This only works when the card is in transparent mode, when the input and output format are the same.
- Input loss selection. The user may select what action the card will take upon physically losing the input: Freeze the image, show a colorbar, zoneplate, grey, black or green image.
- Low Pass Filtering for downconversion.


Fixed:
- SD-SDI 625 in- and output line shift corected.
- SD525 V-flag corrected in TRS.
- GPI Pool selection now works.

- Improved 720p down conversion quality.
- Fixed line on the right side of the picture in variable horizontal downscaling.
- Mute audio on the add-on bus on input loss.
- Clean switching between different scales implemented.
- Quad speed bus timing improved.
- Automatic Input selection between inputs SDI1 and SDI2.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 1405
Hardware version 0101; 0102
Date 2010-06-03
Description Fixed: VITC frame number bug. Frame counter was lagging with respect to the seconds counter.
Fixed: Black output bug. This issue could occur when video signals are (re-)applied to the inputs of the card. (i.e. after switching off/on Sony CCU’s)
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 1204
Hardware version 0100; 0101; 0102
Date 2010-03-05
Description First full release.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Login to MyAXON


Register for MyAXON
Reset password

Sluiten