Download DLA44 firmware

DLA44 firmware

Software version 1510
Hardware version 0100; 0101; 0102; 0200
Date 2012-02-08
Description Linear Acoustic:
- This version is intended for version 1.8.0 of the Up/Down/AutomaxII.
- This version is intended for version 2.6.0 of the AeroMax 5.1.

Changes:
- Added Fixed preset according to EBU-R128 standard
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 1410
Hardware version 0100; 0101; 0102; 0200
Date 2011-12-01
Description Linear Acoustic:
- This version is intended for version 1.8.0 of the Up/Down/AutomaxII.
- This version is intended for version 2.6.0 of the AeroMax 5.1.

Changes:
- Lockmode menu-options changed from: AES1, AES4, Mastercard, Ref1 and Ref2 to AES1, AES4, Mastercard, Reference.
Reference selection is now done by new menu-item Reference Source. This option has a dual function. Reference source not only depicts
to which refernce the cards audio should lock when the lockmode is set to Reference but it is also used to indicate to which reference the Metadata is locked.
Metadata is only generated when the correct ref is selected and present this is done to ensure a clean switch of metadata in the guardband.

- Main output and stereo output are not designated as "dB" anymore as this was incorrect.

- Fixed the generation of CRC packets for metadata. These packets could be incorrect in previous versions

- Fixed the issue when using the output level of the loudness processor as the dialoque level for generating metadata there was no change in dialoque level
if the output level changed.

- Fixed the use of revert metadata presets when there is a loss of incoming metadata and the corresponding menu-item is set tot external metadata as source.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 1209
Hardware version 0100; 0101; 0102
Date 2011-02-23
Description Linear Acoustic:
- This version is intended for version 1.8.0 of the Up/Down/AutomaxII.
- This version is intended for version 2.6.0 of the AeroMax 5.1.

Changes:
- The preset structure has changed over the entire DLAxx range. The first 6 presets in all products are fixed to
the standard Linear Acoustic Presets. Preset 7 to 16 are user adjustable and are at default an exact copy of presets 1 to 6.
Presets 15 and 16 are a copy of preset 1 and also user adjustable.

- The Output level for the loudness processing engine can be set to the approximate loudness level. This is an approximation of
the loudness level therefore we added another menu-option called 2.0 or 5.1 Offset to Output/Dial Level which can be used to fine tune
the output level.

- It is no longer possible to select channel number higher then 8 for the input in the I/O Control Tab when the card is not used with a mastercard.

- The Quadspeed bus is updated to it's latest state which included re-insertion of processed channels on the Quadspeed bus.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 1107
Hardware version 0100; 0101; 0102
Date 2010-12-09
Description DSP Software Versions:
- This version is intended for Up/Down/AutoMaxx version 1.6.0
- This version is intended for AeroMax 5.1 version 2.4.0

- Version 1007 introduced a new way of using the GPI's for controlling the presets and the upmixer at the same time.(Option Preset_Upmix_BCD in menu-item GPI Control)
when the card was controlled by GPI in the mode "Preset_Upmix_BCD" and the 2.0 preset was set to be controlled by GPI. The 2.0 preset did not react on a GPI change.
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 1007
Hardware version 0100; 0101
Date 2010-10-15
Description DSP Software Versions:
- This version is intended for Up/Down/AutoMaxx version 1.6.0
- This version is intended for AeroMax 5.1 version 2.4.0

- added the possibility to use the GPI for preset switching and for the upmixer at the same time.
please see the manual for a detailed explanation
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 0906
Hardware version 0100; 0101
Date 2010-07-30
Description Firmware removed. Please contact support (support@axon.tv) before updating your DLA card


DSP Software Versions:
- This version is intended for Up/Down/AutoMaxx version 1.6.0
- This version is intended for AeroMax 5.1 version 2.4.0

- Fixed the normal bus compatibility. The Quadspeed bus does no longer send audio data over the bus when the card is not used as an add-on card.

- When there was an upmix created from channels 7/8. the upmixer was using channels 1/2 as a source for the LFE channel in the created upmix. This is corrected in this version
- Fixed the missing information about the LFE, Center and the surround channels when a downmix was created.

- Split the options for menu-item GPI Control into options for presets and in options for the upmixer.
Customer can select whether the GPI's should be used for presets or for the upmixer and in what format (Latch, Non-Latched, BCD).

- Added the option GPI_Upmix to the Up_Mix menu-item. The upmixer function can now be controlled by the state of the GPI's.

- Added the option AES7/8_LOUD5.1 to the menu-item Upmixer Input, the name has been changed from AES1/2 into AES1/2_LOUD5.1 for clarity.
The options which have LOUD5.1 in the name are being processed by the AeroMaxx 5.1 Loudness Algorithms before entering the upmixer.

please see the manual for a detailed explanation
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 0604
Hardware version 0100; 0101
Date 2010-05-06
Description - Fixed the reverting/backup of metadata in case of a metadata-loss
- Added the possibility to let the input of the downmixer to be chosen manually or depending on Metadata Loss
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 0503
Hardware version 0100; 0101
Date 2010-01-26
Description - Added Quad Speed Audio Add-On Bus.
- Added fieldupgrade ability for Linear Acoustic firmware.
- Added control for the output limiter drive for the 2.0 processor.
- Added option to follow the 5.1 output level in the 2.0 processor.

- Fixed Mulitband Attack in the 2.0 processor
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download
Software version 0402
Hardware version 0100; 0101
Date 2009-12-23
Description - First Release
Note Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.
  Download