| Software version | 2210 |
|---|---|
| Hardware version | 0200; 0201; 0202 |
| Date | 2012-03-16 |
| Description | This firmware is applicable for: HTI10, HLI20, HL10, SLI20, SLI10 - Fixed fade-out when hold frames were set to zero. - Fixed fade-hold frames for zero fade-in/out frames. - Fixed 'A/B_name-Stat' will now be updated directly when adding or removing a logo. - Fixed status reporting of unknown file formats, like for the old TGA format. - Added selectable logo key filter to reduce visible Chroma milling. Included this new setting in the bundled Cortex panel update. - Factory defaults for alarm objects 'Input', 'EDH-Status' and 'Ref-Status' are changed to have zero priority, alarms disabled. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.<br /><br />WARNING: updating to this version without a key results in a SLI10 |
| Download |
| Software version | 2009 |
|---|---|
| Hardware version | 0200; 0201; 0202 |
| Date | 2011-08-30 |
| Description | This firmware is applicable for: HTI10, HLI20, HL10, SLI20, SLI10 - Fixed unstable LED behaviour at power-up. - Corrected responses to XML RPC protocol. - Corrected A_Name_stat to match length of A_Name preset object. - Added keyer On/Off alarm. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.<br /><br />WARNING: updating to this version without a key results in a SLI10 |
| Download |
| Software version | 1909 |
|---|---|
| Hardware version | 0200; 0201; 0202 |
| Date | 2011-08-03 |
| Description | This firmware is applicable for: HTI10, HLI20, HL10, SLI20, SLI10 - Fixed the loading of Targa files. - Fixed the random all LEDs on state. - Corrected an internal exception handler for the graphics memory. - Corrected clock menu status. - Increased A/B_name string size, to prevent trunctation of error messages. - Corrected GPI pin priority. Now in GPI-ctrl modes 14A, 14B and 7A7B, the high pin numbers have priority over the lower ones. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.<br /><br />WARNING: updating to this version without a key results in a SLI10 |
| Download |
| Software version | 1809 |
|---|---|
| Hardware version | 0200; 0201 |
| Date | 2011-04-22 |
| Description | This firmware is applicable for: HTI10, HLI20, HL10, SLI20, SLI10 WARNING: updating to this version without a key results in a SLI10! Contact our support to obtain a key before updating! - Corrected stack or z-order for fill-output in generator mode, with respect to the Keyer_Top_Layer setting. - Improved watchdog servicing, this prevents corner case card reset. - Fixed crash on loading corrupt PNG files. If a file transfer was abnormally ended, a partial file was stored on Compact-Flash. Solved this unresponsive state of the card. - Fixed file storage crash. Large number of file uploads triggered a memory leak. As result the card became unresponsive. - Fixed the card from disappearing from the crate. Multiple fixes in the control interface driver. - Preview setting removed. Preview output always outputs both preview key signals as layers. - Added missing settings to Cortex Panels. (layer swap, scroll direction, font weight) |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.<br /><br />WARNING: updating to this version without a key results in a SLI10 |
| Download |
| Software version | 1507 |
|---|---|
| Hardware version | 0200; 0201 |
| Date | 2010-09-22 |
| Description | This firmware is applicable for: HTI10, HLI20, HL10, SLI20, SLI10 WARNING: updating to this version without a key results in a SLI10! Contact our support to obtain a key before updating! - Fixed line glitches in logos from Video-RAM. - Fixed SD525 horizontal image start. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.<br /><br />WARNING: updating to this version without a key results in a SLI10 |
| Download |
| Software version | 1406 |
|---|---|
| Hardware version | 0200; 0201 |
| Date | 2010-07-22 |
| Description | This firmware is applicable for: HTI10, HLI20, HL10, SLI20, SLI10 WARNING: updating to this version without a key results in a SLI10! Contact our support to obtain a key before updating! - No changes. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.<br /><br />WARNING: updating to this version without a key results in a SLI10 |
| Download |
| Software version | 1206 |
|---|---|
| Hardware version | 0200; 0201 |
| Date | 2010-01-23 |
| Description | This firmware is applicable for: HTI10, HLI20, HL10, SLI20, SLI10 WARNING: updating to this version without a key results in a SLI10! Contact our support to obtain a key before updating! - Added identity menu items for product features. - Fixed network instability caused by downloading (GET) large files over an FTP or HTTP. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.<br /><br />WARNING: updating to this version without a key results in a SLI10 |
| Download |
| Software version | 1106 |
|---|---|
| Hardware version | 0200; 0201 |
| Date | 2010-01-14 |
| Description | This firmware is applicable for: HTI10, HLI20, HL10, SLI20, SLI10 WARNING: updating to this version without a key results in a SLI10! Contact our support to obtain a key before updating! - Added Control-Keyer "A, B, A+B" menu item. - Fixed "Unknown File Format" error status for Old-Format TGA. - Fixed Card-ID read error. This also solves boot to SLI10, when other product is enabled by feature-key. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.<br /><br />WARNING: updating to this version without a key results in a SLI10 |
| Download |
| Software version | 0905 |
|---|---|
| Hardware version | 0200; 0201 |
| Date | 2009-08-08 |
| Description | This firmware is applicable for: HLI20, HL10, SLI20, SLI10 WARNING: updating to this version without a key results in a SLI10! Contact our support to obtain a key before updating! - Added Preset_Mode control, to select either Logo or Clock functionality in inserter B. - Added 7-segment clock. - Added extra GPI control mode variant - presets assignable to GPI's. - Changed generator mode to output logo preset B over A. Was A-only before. - Fixed picture disturbance when new logo was uploaded. - Added Ping-Pong animation mode. - Added frame-duration in animations. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.<br /><br />WARNING: updating to this version without a key results in a SLI10 |
| Download |
| Software version | 0804 |
|---|---|
| Hardware version | 0200 |
| Date | 2009-06-10 |
| Description | This firmware is applicable for: HLI20, HL10, SLI20, SLI10 WARNING: updating to this version without a key results in a SLI10! Contact our support to obtain a key before updating! - Added Program-Keyers setting to cut all program logo output by one setting. - Added ACP XML-RPC protocol for software control over Backpanel Ethernet connection. (see Manual, Appendix 3) - Fixed HTTP error 404 page not found. Now the unit returns an Applet to enable bootmode like GQW series. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state.<br /><br />WARNING: updating to this version without a key results in a SLI10 |
| Download |
| Software version | 0604 |
|---|---|
| Hardware version | 0200 |
| Date | 2009-04-17 |
| Description | This firmware is applicable for: HLI20, HL10, SLI20, SLI10 WARNING: updating to this version without a key results in a SLI10! Contact our support to obtain a key before updating! - Added Preview keyers. Preview menu selects keyer for a current Edit-Preset. - Added FTP-server for file uploads. - Added OXT file support. - Added a Generator mode with two Fill outputs, and no key. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 0403 |
|---|---|
| Hardware version | 0200 |
| Date | 2009-02-20 |
| Description | WARNING: updating to this version without a key results in a SLI10! Contact our support to obtain a key before updating! - In Logo-Generator mode the Key signal is faded instead of the Fill. - In Logo-Inserter mode black is output when input signal is lost. - Control bus stability and real-time performance is improved. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
Our News & Notes has all information on new products, applications, technical solutions, installations and general affairs. We want to emphasize that contributions are always welcome and we look forward to your article ideas and/or suggestions.