| Software version | 1721 |
|---|---|
| Hardware version | 0102; 0103; 0104; 0105; 0106; 0200; 0201 |
| Date | 2010-12-16 |
| Description | - This software version is intended for Teranex version 1.20.26.1612, included in the download. - Menu-item LicenseKey accepts 16-chararacter key only. - Vi bug resolved |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 1520 |
|---|---|
| Hardware version | 0102; 0103; 0104; 0105; 0106; 0200; 0201 |
| Date | 2010-08-31 |
| Description | - This software version is intended for Teranex version 1.20.25.1612, included in the download. - cadence setting is reapplied after setup - Teranex version Mac address and packet will be announced when changed - auto backup function - phase alignment added |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 1419 |
|---|---|
| Hardware version | 0102; 0103; 0104; 0105; 0106 |
| Date | 2009-10-09 |
| Description | - This software version is intended for Teranex version 1.20.25.1612, included in the download. - Fixed Timecode: Framecounter kept running while TC was stopped. - Fixed S2016 insertion when presets we're changed based on WSS(Products with Upconverter only) |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 1318 |
|---|---|
| Hardware version | 0102; 0103; 0104; 0105; 0106 |
| Date | 2009-09-21 |
| Description | - This software version is intended for Teranex version 1.20.25.1612, included in the download. - Allowed Timecode to be present anywhere in the V-ANC. - Fixed frame-rate conversions |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 1317 |
|---|---|
| Hardware version | 0102; 0103; 0104; 0105; 0106 |
| Date | 2009-07-03 |
| Description | - Fixed Field-bit in OP47 |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 1316 |
|---|---|
| Hardware version | 0102; 0103; 0104; 0105; 0106 |
| Date | 2009-06-23 |
| Description | - This software version is intended for Teranex version 1.20.24.1612, included in the download. - Added WST detection. - Added OP47 detection (added subtitling SD>HD>SD, depending on mode) . - Added OP47 insertion. - Added BPXxx backplane support. - Fixed bug in announcements. - Fixed presets based switching for WSS with SD525 input. - Fixed presets based switching for VI with SD625 input. - Fixed incorrect I-panscan ratio at SD625 to SD625. - Fixed GPI-based preset switching |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 1114 |
|---|---|
| Hardware version | 0102; 0103; 0104; 0105; 0106 |
| Date | 2009-05-05 |
| Description | !!Entire Teranex range is updated to version 1114!! - This software version is intended for teranex version 1.20.21.1612, included in the download. - Improved overall stability. - Fixed Timecode Issues with starting and stopping of VITC and ATC. - Improved both Teranex and Axon upgrade stability. - Improved Teranex Board startup. - Fixed and improved switching between formats. - Fixed and improved switching between aspects. - Fixed wrong aspects at startup. - Fixed Custom aspect ratio issues. - Fixed the End of line spikes bug in the UP converter - Fixed frame-accurate switching based on WSS and VI. - Fixed lineshift in different conversions. - Fixed announcements - Added Cadence control for manual detection of cadences. - Added Clip Video function for clipping illegal values. - Added SMPTE2016 support. - Added 1080p25 to 720p50 conversion support for the HXH40 and HXH41 - Added and fixed Pan and Scan functionality |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 0311 |
|---|---|
| Hardware version | 0102; 0103; 0104; 0105 |
| Date | 2008-06-06 |
| Description | - WSS selects correct preset at startup. - Output format menu item response improved. - This software version is intended for teranex version 1.19.19.1111, included in the download. - removed lockstatus. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 0210 |
|---|---|
| Hardware version | 0102; 0103; 0104 |
| Date | 2008-02-25 |
| Description | - Improved WSS. - Fixed irresponsiveness of card when changing preset. - This software version is intended for teranex version 1.19.19.1111, included in the download. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 0108 |
|---|---|
| Hardware version | 0102; 0103 |
| Date | 2007-12-19 |
| Description | Fixed horizontal movement judder in 720p format. |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 0107 |
|---|---|
| Hardware version | 0102; 0200 |
| Date | 2007-11-29 |
| Description | - Output timing improved |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
| Software version | 0106 |
|---|---|
| Hardware version | 0102; 0200 |
| Date | 2007-11-22 |
| Description | - First release |
| Note | Important notice:<br />Before you upgrade one of your Axon Synapse cards, please check the software version of the rackcontroller (RRC) that you are using. If you are running version 3100 please contact <a href="mailto:support@axon.tv">support@axon.tv</a> to get the newest release of the rackcontroller software. We strongly recommend not to use version 3100 of the rackcontroller software while upgrading your cards as we have experienced some instability during reprogramming which can render your Synapse card in an unusable state. |
| Download |
Our News & Notes has all information on new products, applications, technical solutions, installations and general affairs. We want to emphasize that contributions are always welcome and we look forward to your article ideas and/or suggestions.